- Author:
- David Nickerson <david.nickerson@gmail.com>
- Date:
- 2021-09-15 12:24:03+12:00
- Desc:
- Updates to FHN model:
* Make sure model is valid OpenCOR CellML Text format;
* Make sure model is valid CellML;
* Add SED-ML for single stimulus experiment.
Using OpenCOR snapshot 2021-09-14
- Permanent Source URI:
- https://models.cellml.org/workspace/a1/rawfile/a26c8f6bf655d7de97fbc8d4197ca492804c735a/models/1998_fenton/fenton_karma_model_1998_units_model.xml
<?xml version="1.0"?>
<model xmlns="http://www.cellml.org/cellml/1.1#" name="fenton_karma_model_1998_units_model">
<units xmlns="http://www.cellml.org/cellml/1.1#" name="ms">
<unit prefix="milli" units="second"/>
</units>
<units xmlns="http://www.cellml.org/cellml/1.1#" name="per_ms">
<unit exponent="-1" prefix="milli" units="second"/>
</units>
<units xmlns="http://www.cellml.org/cellml/1.1#" name="mV">
<unit prefix="milli" units="volt"/>
</units>
<units xmlns="http://www.cellml.org/cellml/1.1#" name="per_mV">
<unit exponent="-1" prefix="milli" units="volt"/>
</units>
<units xmlns="http://www.cellml.org/cellml/1.1#" name="per_mV_ms">
<unit exponent="-1" units="mV"/>
<unit exponent="-1" units="ms"/>
</units>
<units xmlns="http://www.cellml.org/cellml/1.1#" name="mS_per_mm2">
<unit prefix="milli" units="siemens"/>
<unit exponent="-2" prefix="milli" units="metre"/>
</units>
<units xmlns="http://www.cellml.org/cellml/1.1#" name="uF_per_mm2">
<unit prefix="micro" units="farad"/>
<unit exponent="-2" prefix="milli" units="metre"/>
</units>
<units xmlns="http://www.cellml.org/cellml/1.1#" name="uA_per_mm2">
<unit prefix="micro" units="ampere"/>
<unit exponent="-2" prefix="milli" units="metre"/>
</units>
<units xmlns="http://www.cellml.org/cellml/1.1#" name="concentration_units">
<unit prefix="nano" units="mole"/>
<unit exponent="-3" prefix="milli" units="metre"/>
</units>
</model>